Saurya Solar Hybrid PCU

Saurya Solar Hybrid PCU (OFF GRID)

Saurya Solar Inverter is a Hybrid PWM based PCU which has Dual Source of Charging, from Solar as well as Grid Power. Solar Charge Controller is designed for maximum utilization of Solar Power with optimum Battery charging and timely shut down of Battery at lower Voltage. It gives a Pure Sine Wave with minimum Distortion.

circuit cuts off the operation, which is indicated by glowing of a Yellow LED on top. The Operation resumes after the input voltage is corrected. The Design of this relay is micro controller based which drives the Relay at the output having a mechanical life of 1 million Cycles.

KEY FEATURES

  • Dual source of charging from Solar Power as well as Grid Power.
  • Regular priority of Solar Power to give maximum benefits from solar energy to run the load or charge the battery.
  • All Critical Parameters displayed on LCD Panel which can be set through switches in front.
  • Maximum usage of Solar Power to minimize the electricity bill and being eco-friendly.
  • Double stage MOSFET over current protection at priority.
  • Thermal trip with auto recovery.
  • Reverse current protection from battery to solar in absence of solar power.
  • Grid Power utilization according to presence of Solar Power.

DISPLAYING PARAMETERS ON LCD

Model VA & Capacity AC Output Voltage Battery Overload Trip
Battery Voltage Discharging Current PV Reverse
PV Charging Current Load Percentage Short-circuit
Grid I/P Voltage Load Status Battery Low/High
Grid Charging Current Battery Status Grid MCB/Fuse Trip

PROTECTIONS

Thermal Trip | Battery High/Low | Short-Circuit | PV Reverse | Grid MCB/Fuse Trip | Overload Trip.

TECHNICAL SPECIFICATIONS

PARAMETERS SAURYA 1450VA SAURYA 2100VA
Nominal Battery Voltage 24V 24V
PV Input 1400Wp 1600Wp
No Load Output Voltage 230V ± 2% 230V ± 2%
Full Load DC Current 55A ± 1.0A 70A ± 1.0A
Full Load O/P Voltage ≥180V ≥180V
Output Voltage Waveform Pure Sine Wave Pure Sine Wave
PWM Charge Controller 45A 45A
Input AC Voltage (Normal) 90V-290V ± 2% 90V-290V ± 2%
Input AC Voltage (UPS Mode) 145V-260V ± 2% 145V-260V ± 2%
Change Overtime (Maximum) ≤ 7msec ≤ 7msec
Grid Charging Current 14.5A ± 1.0A 14.5A ± 1.0A
Default Boost Voltage 28.8V ± 0.2V 28.8V ± 0.2V
Float Voltage 27.4V ± 0.2V 27.4V ± 0.2V
AVR Range in Mains Mode 30% Extra ≤ 180VAC 30% Extra ≤ 180VAC
Battery Low Alarm 21.2V ± 0.2V 21.2V ± 0.2V
Default Battery Low Cut 20.4V ± 0.2V 20.4V ± 0.2V
Overload Protection ≥ 56A ± 1.0A ≥ 71A ± 1.0A
Short-Circuit Protection Yes Yes
Thermal Protection ≥ 95˚C ≥ 95˚C
PV Reverse Protection Yes Yes
Grid MCB/Fuse Trip Yes Yes
  • Fail-Safe Solid-State design, Failure of any component results in NO-INDICATION
  • Models available for 12V DC, 24V AC/DC, 60V AC/DC,110V AC & 230 V AC with Over Voltage Protection